Insulation Boards PDF Print E-mail
Tile Backing Insulation Boards
----------------------------------------

This is the perfect way to insulate any room when laying underfloor heating where an adhesive is required to stick the flooring down (i.e. ceramic, slate, stone, marble, etc).

Uninsulated floors will act as a heat sink absorbing most of the heat energy created by the underfloor heating, if you choose not to insulate the floor before installing underfloor heating you will find that the power usage will be at least double that of the same system with insulation.

By installing insulation between the subfloor and the underfloor heating system the heat energy is forced upwards through the floor covering, this will ensure the rooms ambient temperature is reached more efficiently and allow the thermostat to switch as needed.

By adding insulation boards to your installation you will immediatly save upto 50% on your heating cost compared to installing on a bare subfloor.


Lightweight and very Strong

A high ratio of mechanical strength to weight gives excellent spanning capabilities and makes our insulation boards highly portable and superb on-site managability. They can support weights of 30+ tonnes per meter square.


High Water & Moisture resistance

The closed cell structure of the insulation boards minimises water absorption offering protection against damage or deterioration when exposed to the damp.


Bonding properties

The smooth, dust free, surface provides an optimum base for bonding and laminating.


Application

The generic form of insulation boards are used as an insulation in double glazed doors & windows, caravans, lofts, wall cavity insulation, floors and much more.

What is an insulation board?

A load bearing Insulation Board is similar to a standard construction board, but does not include the cementitious outer face.

PLEASE NOTE THAT THE COLOUR OF BOARDS MAY VARY

Description  (Area divided by 0.72sqm = number of boards required)

Minimum order 6 boards when ordering on-line
Please note that boards are non-returnable
Our  Price
(incl VAT and delivery)
Buy Now
Tile Backing Insulation board 1200x600 x10mm
£9.00
Tile Backing Insulation board 1200x600 x20mm
£10.00
Tile Backing Insulation board 1200x600 x30mm
£12.00
Tile Backing Insulation board 1200x600 x40mm
£13.50
Tile Backing Insulation board 1200x600 x50mm
£15.00

Description  (Area divided by 0.72sqm = number of boards required)

Tile Backing Construction boards consist of an inner sheet of insulation coated with a reinforced, cementitious outer face to give them extra rigidity. This extra rigidity allows the construction board to be used as wallboards to tile on, especially suited for wet situations.

Minimum order 6 boards when buying on-line
Please note that boards are non-returnable

Our  Price
(incl VAT and delivery)
Buy Now
Tile Backing Construction board 1200x600 x6mm
£12.91
Tile Backing Construction board 1200x600 x10mm
£12.91
Tile Backing Construction board 1200x600 x20mm
£15.00
Tile Backing Construction board 1200x600 x30mm
£16.41
Tile Backing Construction board 1200x600 x40mm
£18.18
Tile Backing Construction board 1200x600 x50mm
£19.43

Hi Tack Tape - used to seal joins of insulation products and to hold cold leads neatly in place.
Our  Price
(incl VAT and delivery)
Buy Now
50m Roll self adhesive glass fiber tape
£8.95
The 10mm board is the most popular board board for renovations, but in a new conservatory many people are leaving the floor screed 50mm lower than normal and are using boards up to 50mm thick for greater efficiency and lower running costs.

Underfloor Heating Accessories
Our  Price
(incl VAT and delivery)
Buy Now
Tile Backer Board, Timber floor fixing kit
£13.99
Tile Backer Board, Wall fixing kit
£18.14


Insulation board - Technical details

Insulation is now better than ever before with higher strength and better insulation values making it the number one choice.

Not only is it more cost effective but comes recommended by the market leading adhesives company Granfix. Granfix have carried out a multitude of test with their adhesive and screeding agents and have concluded that our insulation boards are highly compatible.

Technical data for different depths of insulation board

 Board SizesThermal Conductivity (W/mK)Resistance (k-value)U-value (W/m²K)Compressive Strength (kPa)Weight (kgs)

90 days @ 10 °C

1 kPa = 1 kg/cm²30 kgs/m³
1200 x 600 x 10 mm0.0290.372.703500.22
1200 x 600 x 20 mm0.0290.691.453500.45
1200 x 600 x 30 mm0.0291.030.973500.68
1200 x 600 x 40 mm0.0291.380.723500.90
1200 x 600 x 50 mm0.0291.720.583501.13
1200 x 600 x 60 mm0.0292.070.483501.35
Below is a few definitions of common phrases used with insulation. What is important to remember is that the Government have changed the way that houses are rated to be energy efficiency under "Part L" of building regulations.

Resistance
The measure of a material's ability to resist heat flow. The formula for Thermal Resistance is R = L / k where (L) is the material's thickness and (k) is the material's Thermal Conductivity constant. The higher a material's R-value, the better it insulates, and conversely.

Thermal Conductivity
The heat energy that will be transmitted by conduction through 1 square foot of 1 inch thick material in one hour when there is a difference of 1 degree Fahrenheit perpendicularly across two surfaces of the material.

U Value
The rate of heat loss, in British thermal units per hour, through a square foot of a surface (wall, roof, door, windows, or other building surface) when the difference between the air temperature on either side is 1° Fahrenheit. The U-value is the reciprocal of the R-Value.


Insulation technical data sheet

PropertiesStandardUnitData
DensityEN 1602Kg/m²38
Thermal conductivity, 90 days, 10°CISO 8301W/mK0.027
Compressive strength at 10% deflection or yield, (vertical)EN 826kPa350
Compressive modulusEN 826kN/m²12-20,000
Tensile strengthEN 1607kPa500
Tensile modulusEN 1607kPa12-20,000
Shear strengthEN 1209kPa250
Shear modulusEN 1209kPa8,000
Design compressive stress, <2% compressionEN 1606kN/m²110
Water vapour resistivityEN 12086(Uu)- value100-160
Water absorption by immersion (28 days, full boards)DIN 53434Vol-%0.5
Capillarity-nilnil
Coefficient of linear thermal expansionBS 3837: Method 13mm/mK0.07
Temperature limits-°C-50/+75
Fire classificationBs 3837:
Pt2: 1990
--
Edge profile--butt
Surface finish--planed

Comparison chart of other market leaders and our boards.

Properties
Thermal Conductivity (W/mK)
0.027
Compressive Strength (kPa)
300
Water Absorption (Capillarity)
Nil

Last Updated ( Thursday, 24 April 2008 )